FABRICATION BENEFITS
- Sealing components without use of sealant in the vertical façade for efficient and secure installation
- Short fabrication times compared to the use of stud welding to steel substructures approved by the building authorities
- Infill thicknesses between 6 mm and 64 mm can be used. Secure and efficient thanks to patented screw guide
- Roof area with butyl tape sealing and integrated screw guide for maximum installation reliability
- Special basic profiles with positioning guide are available for timber fabricators
TECHNICAL INFOS
- Min. face width
-
- 60 mm
- Uf value of frame (≥)
-
- 1.04 W/(m²·K)
- Max. glass/panel thickness
-
- 64 mm
- Max. sound reduction Rwp
-
- 51 dB(A)
- Air permeability
-
- AE 1350
- Watertightness
-
- RE 1350
- Burglar resistance
-
- Up to RC3
- Wind load resistance
-
- 2.0/3.0 [kN/m²]
- CE marking
-
- Ja
- Surface finishes
-
- Powder
- Anodised
- Paint
- Min.-max. glass/panel thickness
-
- 8…64 mm
- Certificates
-
- Passive house certificate
- Suitable for safety barrier loading
-
- Ja
- Impact resistance
-
- I5/E5
- SYSTEM / MATERIAL
-
- Aluminium
- FAÇADE TYPE
-
- Add-on construction
- Mullion-Transom-Façade
- ENERGY
-
- Thermally insulated
- DESIGN
-
- Appearance of a cover cap
- Max. weight
-
- 280 kg
- Min.-max. face width
-
- 60 mm
- Min. glass/panel thickness
-
- 8 mm
- Face width of pressure plate / cover cap profile
-
- 60 mm
- Face width, outside
-
- 60 mm
- Face width, inside
-
- 60 mm
- Face width of mullion
-
- 60 mm
- Face width of frame
-
- 60 mm
- Face width of transom
-
- 60 mm
- Building authority approval
-
- Ja
- Standards
-
- DIN EN 13830
- General building authority approval
- DIN EN 1627
- Installation angle
-
- 2-105°
- Spandrel safety barriers
-
- Surface-mounted
- Façade-mounted
- Drainage
-
- Ja
- Drainage levels
-
- 3
- Passive house compliant
-
- Ja
- Recyclable
-
- Ja
- Sun shading attachment
-
- Ja
- Skylight construction
-
- Ja
- Polygon façade angle
-
- 20°
- Skylight construction, min. vert. incline
-
- 2°
- Skylight construction, max. vert. incline
-
- 105°
- Skylight construction, min.-max. vert. incline
-
- 2…105°
- Max. unit weight
-
- 280 kg
- Max. glass/infill weight
-
- 280 kg
TENDER SPECIFICATIONS/PREVIEW SPECIFICATION
Schüco AOC 60+ TI, thermally insulated aluminium add-on construction on a timber load-bearing structure (gasket system)
As a mullion/transom construction for multi-storey façades with a 60 mm external face width.
Design features:
The construction must be sealed from outside using aluminium pressure plates to suit the infill thicknesses.
Load-bearing structure:
Selection
The load-bearing structure of the façade construction must be fabricated from suitable types of wood.
Or
The load-bearing structure of the façade construction is to be fabricated from suitable types of wood supplied by the customer.
End
Wood quality, design and surface treatment are described separately. The necessary cross sections must be calculated according to DIN 1052. Furthermore, DIN EN 942 (Wood in joinery work), DIN 1055 (Anticipated loads for buildings) and “Technical regulations for the use of glazing with linear supports, DIBt, September 1998 edition” must be taken into account in the design of the construction. The load-bearing wood construction is on the inside. In faceted façades, the width of the wood profile must not exceed 60 mm if insert units are planned to be installed.
The glazing system consists of aluminium cover caps and/or pressure plates (clamping connection). The joint between the pressure plates and the load-bearing structure must be designed in accordance with the conditions of the existing general building authority approval. The glazing system is attached to the load-bearing structure using an aluminium basic profile by means of screw connections. The aluminium profiles have alternating holes 125 mm apart for this purpose. A large-volume EPDM gasket with integral ventilation channels, structural height 15 mm, forms the basis for the installation of the glazing and the ventilation of the construction. The joints of the gaskets to be laid horizontally and vertically must overlap and be sealed. The corresponding alternating notches must be made in accordance with the system manufacturer’s recommendations.
Glazing / insert units:
All glazing, even in the insert units, lies in the same plane.
The glazing gaskets made from weather-resistant, black EPDM on the room side are of different depths in the mullions and transoms (6 mm offset).
Two individual gaskets made from weather-resistant, black EPDM, with a height of 5 mm, are positioned on the outside. Moulded gasket intersections made from EPDM must be used where mullions and transoms join.
Ventilation:
Rebate base ventilation and vapour pressure equalisation are achieved at all four corners of each module field into the mullion rebate.
For field drainage and ventilation, appropriate openings must be made in the aluminium pressure plates, cover caps and gaskets.
Dimensions and design of the exterior cover caps:
Cover cap (mullion) U-shaped 60 x 30 mm
Cover cap (transom) rectangular 60 x 8.5 mm
CAD DATA
-
Mullion section detail, aluminium basic profile, Schüco AOC 60 TI.SI, passive-house certified
-
Transom section detail, aluminium basic profile, Schüco AOC 60 TI.SI, passive-house certified
TEST DOCUMENTS
Type of document |
|
Doc. no. / Download | |||||||||||||
Product passport |
|
11/11-A385-L2_en (pdf, 88 KB) | |||||||||||||
System test report |
|
PHi_Schrägv_AOC 60 TI.SI_en (pdf, 947 KB) | |||||||||||||
System test report |
|
PHI_PF_RI_AOC 60 TI.SI_en (pdf, 2 MB) |