Door ADS 80 FR 30 for 30 minute fire resistance

The door and wall construction for multi-purpose applications, which has been tested in accordance with European standards (EN 1364 / 1634) and German standards (DIN 4102), fulfils all the requirements of fire protection classes EI30 (T30 / F30) and EW30

The series is based on highly stable 5-chamber hollow profiles with a basic depth of 80 mm and is also suitable for generous clear openings. In conjunction with optional fittings components, tailor-made multi-purpose doors can be created to meet additional requirements for building security and automation, e.g. burglar resistance up to RC 3, panic function, safety barrier loading, access control and sound reduction. Floor-to-ceiling, large glass formats and fixed glazing for indoor use that is suitable for safety barrier loading are also possible.

For special requirements such as those applicable to exits in nurseries, Schüco offers solutions for fire and smoke protection which ensure that the emergency exit door function is triggered using a door handle with an installation height of 1500 mm. Anti-finger-trap doors can also be installed. In addition, the use of profile-integrated door closers with a free swing function enables easy-access openings, which can also be used by smaller children or older people without any problems.

หมวดหมู่:
PRODUCT BENEFITS

Design

  • Clear opening dimensions up to 1400 mm x 2988 mm and floor-to-ceiling glazing up to 1400 mm x 3000 mm for maximum transparency
  • Standard and angled glazing beads and centre glazing broaden the range of possible designs
  • Concealed fittings such as door hinges, door closers and pre-selector for an elegant appearance
  • Vertical silicone joints: combination of fixed glazing with corner constructions for inner and outer corners enable very narrow face widths

Automation

  • Side-hung door drives approved
  • Emergency exit switches for securing exit areas
  • Access control systems in combination with Schüco Door Control System (DCS) possible
  • Schüco locks with electric coupling for access control; also with day setting
  • Schüco electric locks for single and multi-point locking up to RC 3: variable security depending on requirements

Security

  • Anti-finger trap protection: e.g. for side-hung door drives or use in nurseries to secure the secondary closing edges
  • RC 2 burglar resistance with latch and bolt locks for single and double-leaf doors
  • Fixed glazing with safety barrier loading, tested and approved in accordance with DIN EN 12600 and TRAV
  • Uniform, fully tested and certified range of fittings
  • Approved for internal and external single and double-leaf doors as well as fixed glazing

TECHNICAL INFOS

System basic depth
  • 80 mm
Min. face width
  • 137 mm
Uf value of frame (≥)
  • 1.9 W/(m²·K)
Max. glass/panel thickness
  • 42 mm
Max. sound reduction Rwp
  • 46 dB(A)
Air permeability
  • Class 4
Watertightness
  • Class 9A
Burglar resistance
  • Up to RC3
Wind load resistance
  • B2
  • A3
Area of application
  • External use
  • Internal use
Proof of durability
  • 200,000 cycles in accordance with DIN EN 12400
  • 1,000,000 in accordance with DIN EN 12400
Security system
  • Ja
Min.-max. glass/panel thickness
  • …42 mm
Mechanical strength
  • Class 4
  • Class 3
  • Class 2
Suitable for safety barrier loading
  • Ja
Concealed fittings system
  • Ja
Max. height
  • 3047 mm
Max. width
  • 2938 mm
Min.-max. height
  • 1732…3047 mm
Min.-max. width
  • 625…2938 mm
Max. clear opening dimension (w x h)
  • 2820 x 2998 mm
Min. clear opening dimension (w x h)
  • 460 x 1648 mm
Type of design
  • Single-vent
  • Double-vent
  • Single-vent and side section
  • Double-vent and side section
  • Single-vent with toplight
  • Double-vent with toplight
  • Single-vent with toplight and side section
  • Double-vent with toplight and side section
  • Single-vent with side section, right
  • Single-vent with side section, left
  • Single-vent with side section, right and left
  • Single-vent with side section and toplight
  • Double-vent with side section, right
  • Double-vent with side section, left
  • Double-vent with side section, right and left
  • For use in glazing
  • For use in façade
Special applications
  • Anti-finger-trap door
  • Opposed opening door
  • Butt joint glazing
  • Floor plan, angled glazing
Max. weight
  • 280 kg
Fire protection
  • EI30
  • F30
  • T30
  • G30
  • EW30
Smoke protection
  • SA
  • S200
Standards
  • DIN EN 1627
  • DIN 4102
  • EN 1634
  • EN 13501-2
  • DIN 18095
  • 200,000 cycles in accordance with DIN EN 12400
  • 1,000,000 in accordance with DIN EN 12400
  • EN 1364
  • Class 8
SYSTEM / MATERIAL
  • Aluminium
ENERGY
  • Thermally insulated
FUNCTIONS
  • Fire protection
  • Smoke protection
  • Burglar resistance
  • Increased security
  • Interior design
Max. glass size (w x h)
  • 1400 x 3000 mm
Use
  • Door
  • Fixed glazing
Direction of opening
  • Inward and outward
  • Finger-trap protection
  • Single and double-vent
  • Outward
  • Inward
Emergency exit door
  • Ja
Installation option
  • Vertical
Basic protection against vandalism
  • Ja

TENDER SPECIFICATIONS/PREVIEW SPECIFICATION

CAD DATA

TEST DOCUMENTS

BROCHURES