Firestop T90 / F90 for 90 minute fire resistance

The door and wall construction for fire-resistant applications, which has been tested in accordance with European standards (EN 1364 / 1634) and German standards (DIN 4102), fulfils all the requirements of the fire resistance class EI90 (T90 / F90)

This Schüco fire and smoke protection series is based on highly stable multi-chamber profiles with a basic depth of 105 mm and is also suitable for generous clear openings. The fully approved aluminium doors and wall units prevent the uncontrolled spread of fire for a period of 90 minutes. In conjunction with optional fittings components, tailor-made multi-purpose doors can be created to meet additional requirements for building security and automation, for example panic function, access control and sound reduction (internal tests).

หมวดหมู่:
FABRICATION BENEFITS
  • Fittings installation in the multi-purpose groove uniform and flexible thanks to locking cams, which are pre-installed in the factory
  • Wide range of installation accessories: units can be fixed to the building structure quickly and economically

TECHNICAL INFOS

System basic depth
  • 105 mm
Min. face width
  • 148 mm
Uf value of frame (≥)
  • 1.7 W/(m²·K)
Max. glass/panel thickness
  • 58 mm
Max. sound reduction Rwp
  • 44 dB(A)
Area of application
  • External use
  • Internal use
Proof of durability
  • 200,000 cycles in accordance with DIN EN 12400
Security system
  • Ja
Min.-max. glass/panel thickness
  • …58 mm
Max. height
  • 2672 mm
Max. width
  • 3040 mm
Min.-max. height
  • 1945…2672 mm
Min.-max. width
  • 830…3040 mm
Max. clear opening dimension (w x h)
  • 2648 x 2493 mm
Min. clear opening dimension (w x h)
  • 648 x 1870 mm
Type of design
  • Single-vent
  • Double-vent
  • Single-vent and side section
  • Double-vent and side section
  • Single-vent with toplight
  • Double-vent with toplight
  • Single-vent with toplight and side section
  • Double-vent with toplight and side section
  • Single-vent with side section, right
  • Single-vent with side section, left
  • Single-vent with side section, right and left
  • Single-vent with side section and toplight
  • Double-vent with side section, right
  • Double-vent with side section, left
  • Double-vent with side section, right and left
  • For use in glazing
Special applications
  • Anti-finger-trap door
Max. weight
  • 300 kg
Fire protection
  • F90
  • T90
  • EI90
Smoke protection
  • RS1
  • RS2
Standards
  • DIN 4102
  • EN 1634
  • DIN 18095
  • EN 1364
SYSTEM / MATERIAL
  • Aluminium
ENERGY
  • Thermally insulated
FUNCTIONS
  • Fire protection
  • Smoke protection
  • Burglar resistance
  • Increased security
  • Interior design
Max. glass size (w x h)
  • 1500 x 2500 mm
Use
  • Door
  • Fixed glazing
Direction of opening
  • Inward and outward
  • Side-hung
  • Single and double-vent
Emergency exit door
  • Ja
Installation option
  • Vertical

TENDER SPECIFICATIONS/PREVIEW SPECIFICATION