Design features:
Special fire boards are inserted in the aluminium hollow profiles.
The composite profile must be secured using stainless steel bridges.
In the area of the vent rebates, the insulating bars and the centre gaskets are fitted with gasket cords, which guarantee sealing in the event of a fire.
Only tested fire-resistant glass and/or infills that are listed in the classification report may be used.
All fire-resistant glass is sealed in using external and internal EPDM gaskets.
Only tested fittings belonging to the system may be used.
Profile basic depths:
Outer frame 70 mm
Vent frame 80 mm
Profile face widths:
Outer frame 79 mm
Insert outer frame 59 + 10 mm
Vent frame 51 mm
The units must be delivered with a CE marking and a Declaration of Performance and confirmation of installation.
The units must be installed in accordance with the guidelines of the installation, maintenance and cleaning instructions.
BROCHURES
-
Aluminium
Schüco AWS 60 FR 30 / AWS 70 FR 30