Fire-resistant glass

SchücoFlam fire-resistant glass approved for the Schüco Door ADS 80 FR 30, Firestop II, FW 50+BF and FW 60+BF systems. Due to the maximum glass sizes of 1400 x 3000 mm (for Schüco Door ADS 80 FR 30), the glass offers a wide variety of uses both internally and externally. SchücoFlam glazing can be installed with satin finish or with mesh-like design as an individual design unit.

หมวดหมู่:
FABRICATION BENEFITS

 

  • Fire-resistant glass for 30 to 90 minute fire resistance
  • Multi-functionality thanks to almost limitless combinations
  • Burglar resistance, safety barriers, noise reduction, thermal insulation, solar shading can also be combined
  • Safety glass in accordance with DIN 1249 / 1259
  • Glazing unit composition with toughened safety glass – good handling and lower risk of breakage
  • Only one glass thickness for all glass sizes
  • Rigid edge seal
  • Minimum weight
  • High thermal insulation properties with double glazing up to Ug = 1.0 W/m²K

TECHNICAL INFOS

System basic depth
  • 16 mm
Max. glass/panel thickness
  • 52 mm
Max. sound reduction Rwp
  • 47 dB(A)
Burglar resistance
  • Up to RC3
  • Up to RC2
  • Up to RC1
  • Up to RC1 N
  • Up to RC2 N
  • Max. P4A
Area of application
  • External use
  • Internal use
Security system
  • Ja
Min.-max. glass/panel thickness
  • …52 mm
Suitable for safety barrier loading
  • Ja
Max. height
  • 3000 mm
Max. width
  • 1500 mm
Min.-max. height
  • 300…3000 mm
Min.-max. width
  • 200…1500 mm
Max. weight
  • 260 kg
Fire protection
  • EI30
  • F30
  • F60
  • F90
  • T30
  • T60
  • T90
  • G30
  • EI60
  • EI90
  • EW30
  • E30
  • EW60
Standards
  • DIN 4102
  • EN 1634
  • EN 13501-2
SYSTEM / MATERIAL
  • Glass
ENERGY
  • Highly thermally insulated
  • Thermally insulated
FUNCTIONS
  • Fire protection
Max. glass size (w x h)
  • 1500 x 3000 mm
Use
  • Window
  • Door
  • Façade
  • Fixed glazing
Basic protection against vandalism
  • Ja

TENDER SPECIFICATIONS