- Simple clipping into the outer frame recesses ensures efficient fabrication and installation
- Modular system configuration guarantees integration of the ventilators in almost all window and sliding systems with basic depths of 50 mm to 184 mm
TECHNICAL INFOS
- Air permeability
-
- Class 3
- Watertightness
-
- Class 9A
- Dimensions (w x h x d)
-
- 50 x 277 x 50-184 mm
- for system basic depths
-
- 50 – 184
- Min. unit width
-
- 400 mm
- Ventilation type
-
- Natural
- Max. sound reduction Dn,e,w
-
- 52 dB(A)
TENDER SPECIFICATIONS
PREVIEW SPECIFICATION
Schüco VentoFrame
Thermally broken ventilator with self-regulating ventilation flap for integrated installation into recesses in the upper horizontal outer frame profile / extension profile.
Adapters allow the ventilators to be altered for the required basic depth. Inflowing external air is diverted into the interior of the room by directing the air flow underneath the ceiling of the residence. In the event of high wind speeds, the outer ventilator flap automatically regulates the inflowing air so that no draughts occur. The maximum air supply into the interior can be manually limited in four stages via the flap profile.
The flap profile on the inside and the drip protection bar on the outside span the entire width of the window and conceal the individual plastic ventilators. The grating inserted on the inside acts as a flyscreen and can be removed for cleaning. There is the option to insert pollen protection in place of the flyscreen.
An additional sound reduction attachment can be combined with the ventilator to improve the sound reduction properties.
Material:
Ventilator: black plastic
Flap profile and drip protection bar: mill finish aluminium (coatable)
End caps: black plastic
Operating options:
Flap profile, operating rod or pull cord
Fabrication data block:
Minimum face width of the necessary outer frame / extension profile: 74 mm
Necessary recess in the outer frame profile per ventilator: 277 mm x 48.5 mm
Installation depth: 50 mm – 184 mm
Tests* and standards
Sound reduction in accordance with EN ISO 10140-2 and EN ISO 717-1:
Ventilator sound reduction Dn,e,w (C;Ctr), open: 33 (0;-1) dB
Ventilator sound reduction Dn,e,w (C;Ctr), closed: 43 (-1;-2) dB
Ventilator sound reduction with sound reduction attachment D n,e,w (C;Ctr), open: 40 (0;-1) dB
Ventilator sound reduction with sound reduction attachment D n,e,w (C;Ctr), closed: 49 (-1;-3) dB
Volume flow key values in accordance with EN 13141-1
Air flow per ventilator at 2 / 4 / 8 Pa 5.8 / 10.0 / 13.7 m3/h
Air flow per ventilator with sound reduction attachment at 2 / 4 / 8 Pa 4.7 / 6.1 / 8.6 m3/h
Tested in combination with windows in accordance with DIN EN 14351-1
Watertightness and air permeability of joints are classified in accordance with DIN EN 12207 and DIN EN 12208: watertightness guaranteed up to 600 Pa when open and closed.
*Test values are valid for AWS 75.SI+ and were determined without pollen filters.
TEST DOCUMENTS
Type of document |
|
Doc. no. / Download | |||||||||||||||||||||||||||||||||||||||||||
Test report |
|
16-001772-PR01_EN (pdf, 288 KB) | |||||||||||||||||||||||||||||||||||||||||||
Classification report |
|
16-001772-PR01_EN (pdf, 3 MB) |
BROCHURES
-
Aluminium
Schüco VentoFrame