Fabrication benefits
- Slim face widths of 50 and 60 mm for maximum light penetration
- Variety in design due to wide range of aluminium cover caps
- Special profiles for wall attachments and insert units
- Flexible use of infill units in 20 to 40mm thickness
- Elegant intersection of skylight and vertical façade
- High level of thermal insulation
- TRAV-tested
- CE conformable
Technical information
Uf value of frame (≥)1.2 W/(m²·K)
Min. face width50 mm
Max. glass/panel thickness70 mm
Max. weight1800 kg
Surface finishesRAL, Powder, Paint
Air permeabilityAE
Max. sound reduction Rwp47 dB(A)
WatertightnessRE 1200
Impact resistanceClass 5
Burglar resistanceUp to RC4
Suitable for safety barrier loadingYes
Bullet resistanceUp to FB6
Min. basic depth of mullion50 mm
Max. basic depth of mullion280 mm
Min.-max. basic depth of mullion50…280 mm
Max. face width60 mm
Min.-max. face width50…60 mm
Min. glass/panel thickness6 mm
Min.-max. glass/panel thickness6…70 mm
Max. glass/infill weight1800 kg
Installation angle0-15°
Polygon façade angle15°
DrainageYes
Drainage levels2
Wind load resistance2.0 [kN/m²]
Sun shading attachmentYes
Security systemYes
CertificatesEPD
CE markingYes
RecyclableYes
StandardsEN ISO 10077, DIN EN 13830, EN 1522
CWCT certifiedYes
Building authority approvalYes
Colour-independentYes
Documentation
Order and technical manual 2-2 – Fire-resistant façades
Façade Systems – VISS
Order and fabrication manual – VISS RC
Architecture in steel and glass
Test documents
Document type | Test type | Result | Classification | Document no. / Download |
---|---|---|---|---|
Prüfbericht | Einbruchhemmung Einbruchhemmung |
RC3 RC3 |
RC3 | View onlineDownload (pdf, 521.9 KB) |
Prüfbericht | Pendelschlagversuch | Kategorie A | View onlineDownload (pdf, 563.9 KB) | |
Prüfbericht | Pendelschlagversuch | Kategorie A | View onlineDownload (pdf, 954.5 KB) | |
Prüfzeugnis | Beschuß | FB4 NS | FB4 NS | View onlineDownload (pdf, 169.2 KB) |
Prüfzeugnis | Beschuß | FB5 S | FB5 S | View onlineDownload (pdf, 1.6 MB) |
Gutachterliche Stellungnahme | Luftdurchlässigkeit Schlagregendichtheit Widerstand gegen Windlast Pendelschlagversuch |
Klasse AE Klasse RE 1200 2000 Pa/ 3000 Pa I5 / E5 |
Klasse AE Klasse RE 1200 2000 Pa/ 3000 Pa I5 / E5 |
View onlineDownload (pdf, 323.9 KB) |
Gutachterliche Stellungnahme | Einbruchhemmung Einbruchhemmung |
RC2 RC2 |
EN 1627 | View onlineDownload (pdf, 596.3 KB) |
Gutachterliche Stellungnahme | Einbruchhemmung | RC3 | View onlineDownload (pdf, 947.7 KB) | |
Gutachterliche Stellungnahme | Schallmessung | View onlineDownload (pdf, 93.1 KB) | ||
Gutachterliche Stellungnahme | Schlagregendichtheit | AE, RE 1200, 2000 Pa, I5/E5 | CE Leistungswerte RC3 | View onlineDownload (pdf, 323.9 KB) |
1-10 of 13