Energy
- Structural glazing façade with thermal break, e.g. as highly insulating HI variant
Design
- Inside face width 85 mm
- Three glazing types provide considerable design freedom: stepped insulating glazing, standard insulating glazing with UV-resistant edge seal, and standard insulating glazing with continuous glazing beads
Automation
- Opening units fully integrated in the load-bearing structure, also in conjunction with concealed motor drive
Security
- European Technical Approval (ETA-07-0120)
Enhanced function
- Insert units possible as projected top-hung or parallel-opening windows with vent weights up to 250 kg
TECHNICAL INFOS
- System basic depth
-
- 228 mm
- Min. face width
-
- 85 mm
- Uf value of frame (≥)
-
- 3.4 W/(m²·K)
- Max. glass/panel thickness
-
- 55 mm
- Max. sound reduction Rwp
-
- 43 dB(A)
- Air permeability
-
- AE
- Watertightness
-
- RE 1200
- Wind load resistance
-
- Class C2 / B2
- CE marking
-
- Ja
- Max. vent weight
-
- 250 kg
- Surface finishes
-
- Powder
- Anodised
- Paint
- Min.-max. glass/panel thickness
-
- 28…55 mm
- Suitable for safety barrier loading
-
- Ja
- Impact resistance
-
- I5/E5
- Max. height
-
- 3600 mm
- Max. width
-
- 2700 mm
- Min. system basic depth
-
- 19 mm
- Min.-max. system basic depth
-
- 19…228 mm
- SYSTEM / MATERIAL
-
- Aluminium
- FAÇADE TYPE
-
- Mullion-Transom-Façade
- ENERGY
-
- Thermally insulated
- DESIGN
-
- Appearance of a cover cap
- Concealed Insert units
- Max. weight
-
- 480 kg
- Max. system basic depth
-
- 228 mm
- Min.-max. face width
-
- 85 mm
- Min. glass/panel thickness
-
- 28 mm
- Min. basic depth of mullion
-
- 19 mm
- Max. basic depth of mullion
-
- 228 mm
- Min.-max. basic depth of mullion
-
- 19…228 mm
- Face width of pressure plate / cover cap profile
-
- 85 mm
- Face width, outside
-
- 85 mm
- Face width, inside
-
- 85 mm
- Face width of mullion
-
- 85 mm
- Face width of frame
-
- 85 mm
- Face width of transom
-
- 85 mm
- European Technical Assessment
-
- Ja
- Drainage
-
- Ja
- Drainage levels
-
- 3
- Recyclable
-
- Ja
- Concealed opening unit
-
- Ja
- Polygon façade angle
-
- 20°
- Butt joint width
-
- 20 mm
TENDER SPECIFICATIONS/PREVIEW SPECIFICATION
Schüco SFC 85.HI type B, highly thermally insulated self-supporting aluminium façade system with multi-pane insulating glass and silicon edge seal
As a mullion/transom construction for multi-storey façades with an internal face width of 85 mm and without external pressure plates and cover caps, 20 mm wide joints between the insert units from the outside and flush-fitted integration of the insert units in the load-bearing structure.
Approval:
Planning, calculation and design must be in accordance with the conditions of the European Technical Approval (ETA), approval number ETA-07/0120. Designs that differ from the ETA require project-specific approval from the respective supreme building authority.
Façade load-bearing structure:
The load-bearing structure of the façade construction consists of rectangular multi-chamber hollow profiles.
The load-bearing profiles are on the room side.
All profile edges are rounded.
The gasket locating groove of the transom overlaps the gasket locating groove of the mullion/assembly mullion.
On multi-storey façades, all horizontal joints must be constructed using the joint connectors and joint tolerance pads belonging to the system. Appropriate profile components which also have a face width of 85 mm must be used for vertical expansion and assembly joints.
2-part transoms with motor are used for electrically-operated projected top-hung or parallel opening insert units.
The overlap area is sealed through the fold-out rebate gasket; the gasket leg is notched, allowing the gasket to be inserted in the joint area.
Insert units, fixed / parallel-opening window / projected top-hung:
The insert frames for fixed glazing consist of thermally insulated frame profiles with 17.5 mm deep insulating bars pre-rolled and additional inserted dark bronze anodized profiles for bonding with the panes of insulating glass. The basic depth of the insert frames is 85 mm (adhesive surface outside up to inside edge of vent). The units are inserted flush in the mullion/transom load-bearing structure.
The insert outer frames have a continuous front chamber gasket with 2 fins outside and a glazing rebate gasket inside. The insert units are also connected inside and outside to the rebate gaskets in the load-bearing structure.
The load transfer (dead load) for the fixed lights is via unit carriers arranged horizontally at the bottom. The negative wind loads are dispersed via reversed, laterally arranged hook-in clips and horizontally arranged fixing cleats.
The load transfer (dead load and negative wind load) for the moving vents is via stainless steel fittings.
Glazing:
The insulating glass must be designed as multi-pane insulating glass. Glazing/panel thicknesses of 28-45 mm may be used.
In the production of double glazed units, a pane of heat soaked toughened safety glass is used on the outside.
The room-side pane consists of float glass/plate glass…….The edge seals of the insulating glass panes must be resistant to UV radiation. The panes of glass must have arris edges (finely adjusted). The construction details, e.g. the dimensioning of bonded joints must be agreed with the supplier of adhesives and sealants.
The panes must be supported using glazing supports from the system. From an installation height of 8 m, the units must also be secured individually with glass securing clips.
Storey-height glazing with safety requirements in accordance with TRAV must be secured individually with additional glass securing clips.
Profile face widths:
Mullion, transom 85 mm
Profile basic depths:
Mullion 19/40/51/75/105/125/150/175/200/225 mm
Assembly mullion 75/105/125/150 mm
Transom 6/39/50/74/104/124/149/174/199/224 mm
Transom with motor 74/104/124/149/174/199/224 mm
CAD DATA
-
Mullion, fixed light Schüco SFC 85
-
Assembly mullion, fixed light Schüco SFC 85
-
Transom, fixed light Schüco SFC 85
TEST DOCUMENTS
Type of document |
|
Doc. no. / Download | |||||||||
Classification report |
|
10231171/1_en (pdf, 2 MB) | |||||||||
Classification report |
|
280166/5969/CPD (pdf, 9 MB) | |||||||||
Classification report |
|
10831171_en (pdf, 8 MB) | |||||||||
Classification report |
|
10231171/2_en (pdf, 2 MB) | |||||||||
Classification report |
|
10835363_en (pdf, 7 MB) |